CA-5 SATEL
7
• Access code No. 5 - does not disarm for other users – permits disarming only when the
same access code was used for arming the system, which makes it possible to control
(block) access to the site for the user who has such an access code at his disposal.
The service code provides access to some of the user functions (besides creating and
deleting the users, and arming or disarming the system).
4.6 A
RMED
M
ODE OF THE
C
ONTROL
P
ANEL
In order to adjust the security system to various situations, the CA-5 control panel offers
several armed modes:
4.6.1 Full armed mode
The operating mode when detectors connected to the control panel control the
protected site and violation of the protected areas is signaled by the control panel with
any available means (monitoring, sirens, keypad).
4.6.2 Silent armed mode
The supervision mode during which the alarms are transmitted to the monitoring station,
signaled in the keypad, and on the K
EYPAD ALARM
type of output.
4.6.3 Partial armed mode with no exit from the site
The armed mode with automatic bypassing of the zones (detectors) assigned by the
installer. If, after arming the system, the user has not left the site and has not violated
the entry/exit monitoring line during the exit delay, the selected zones of the control
panel will be automatically bypassed, and activation of the detectors connected to those
zones will trigger no alarm.
4.7 A
RMING
[CODE][#]
The arming is only possible when the system is signaling no alarm and it is not in the armed
mode: the ALARM and ARMED LEDs are off.
In order to arm the system, enter the user access code and confirm it with the [#] key. If you
made a mistake when entering the access code, press the [
*
] key and re-enter the code. The
access codes should be entered very carefully. Three consecutive mistakes may trigger the
alarm recorded in the events log as the „3 wrong codes alarm”.
If the code is entered correctly and arming is possible, the control panel will confirm the entry
with four short beeps followed by a long one and will get armed. In case the installer has pre-
programmed the „exit delay”, the ARMED LED will start blinking to indicate beginning of that
time countdown, and arming will take place when the countdown is over. The LCD keypad
will display information about exit time delay.
The installer determines the length of the exit delay and the way the audible signaling works.
EXAMPLE: Arming with the user access code: 39763.
press in turn: [3][9][7][6][3] [#]
The control panel may fail to arm the system if:
• the panel is not ready for arming the system: there are zones indicated by the installer
which must not be violated while the system is being armed („priority” option) and one
of them is being violated – the panel signals this state with three long beeps and displaying
the names of violated zones on LCD keypad.
In such a situation, you should wait until all the zones are ready (in the LED keypad the
LEDs 1÷5 will go out; in the LCD keypad – symbols of zone violation) and then arm the
system again (enter the access code). If one of the zones remains all the time violated
(in the LED keypad one of the LEDs 1÷5 is always on, in the LCD keypad the symbol of