USER FUNCTIONS MENU:
F
UNCTION
N
R
F
UNCTION NAME
0 Start DWNL (starts panel programming by the phone from service computer)
1 Change access code
2 Add user (adds new user code)
3 Erase user (deletes user code)
4 Bypass zones
5 Arm silent (activates silent armed mode)
6 Set time (programs panel clock)
7 MONO outputs (MONO
SWITCH
output on)
8 BI outputs (BI
SWITCH
output on/off)
9 Power supply RESET on RESETTABLE
POWER
outputs type
10 Events (only in LCD keypad)
11 Outputs & LEDs test
12 Service access
Notes:
• The functions 2, 3 and 12 are available to the master user only, while the functions 0,10
and 11 - to the master user and the service.
• Pressing the [
*
] key at any time makes the control panel quit the user function mode.
• Having performed the function (or having refused to perform it), the control panel always
quits the user function mode. To carry out a next function you must re-enter the access
code, confirm it with the [
*
] key, select the function number and confirm it by pressing the
[#] key.
• Refusal to perform the function is signaled with three long beeps (e.g. after calling the
function 2, when all the access codes are already entered).
6.1 S
TART
D
OWNLOAD
[CODE][
*
][0][#]
The function connects the control panel by telephone with the service computer for remote
programming of the security system parameters and downloading the event memory log. The
function can be called by the master user and the service.
The computer program makes available to the computer operator a keypad working
simultaneously with the real keypads installed in the system, and provides detailed
monitoring of the system, including the status of its zones and outputs. The knowledge of the
users' access codes makes it possible to use the computer pad in the same way as any
additional system keypad (most of the user functions are available).
On activating the function, the panel engages the telephone line and connects to the service
computer. During the data exchange the telephone line will be busy. The service can
temporarily free the telephone line by suspending the downloading, and then calling the
control panel again to continue the data exchange. The installer should make the users
aware of it so that they will not answer the incoming calls to allow re-establishing of the
connection and correct completion of the transmission.
The function is called in the same way as the user function 5.
Connection between the control panel and the computer (after the panel is appropriately
programmed) can be initialized from outside by the computer calling the control panel, and
also can be effected by the installer in local mode using the corresponding service function.