User Manual CA-5
18
[6] [#]
-
calling the number of the „panel clock programming” function confirmed
with two short beeps and fast blinking of the PROGRAM diode. The first
digit (1) is displayed on the LEDs,
[
*
] [
*
] - (5)
[
*
] [
*
] - (3)
[
*
] [
*
] - (9)
[
*
] [
*
] - two long beeps (the LED indications remain unchanged),
Note: Pressing the [
*
][#]
keys will
quit the function, while for checking the date setting, it is
necessary to press the [#]
key.
[#] - going over to the date checking step (pressing the [#] key - at this moment -
will generate the „Clock programming” event), downloading of next digit (0),
[
*
] [
*
] - (9)
[
*
] [
*
] - (1)
[
*
] [
*
] - (1)
[
*
] [
*
] - two long beeps (the LED indications remain unchanged),
[
*
] [#] - quitting the function without changing the date, signaled by two long beeps.
The following data have been downloaded from the control panel:
time:
15:39
date: September 11
6.8 MONO
OUTPUTS
[CODE][
*
][7][#]
The purpose of the function is determined by the installer. It can, for instance, activate
electromagnetic locks, bells, signaling lamps or any other devices. The function is available
when the MONO
SWITCH
type has been selected for one of the outputs.
Using this function switches on the output for a time specified by the installer. Performance is
confirmed by four short beeps and a long one.
The function is called in a similar way as for the user function 5.
6.9 BI
OUTPUTS
[CODE][
*
][8][#]
The purpose of the function is determined by the installer. It can be used, for example, for
switching on the external lighting or any electrical devices.
The function is active when the BI
SWITCH
type is selected for one of the outputs.
Using the function permanently changes over the output status. If the output is off, the
function will switch it on, and if it is on, the function will switch it off.
Switching the output on is confirmed by the keypad with four short beeps and a long one,
while switching it off - with three short beeps.
The function is called in the same way as the user function 5.
6.10 P
OWER
S
UPPLY
R
ESET
[CODE][
*
][9][#]
The function is used for handling special detectors equipped with individual on/off memory,
which is cleared by shutting down power supply (for example, smoke detectors). Calling the
function temporarily disconnects power supply for such detectors.
The function is active when the RESETTABLE
POWER
type is selected for one of the outputs.
The function is called in the same way as the user function 5.
6.11 E
VENTS
[
FUNCTION
10
–
ONLY
LCD
KEYPAD
]
The function is available in LCD keypad and makes it possible to view the whole contents of
the events log (the last 255). To view the events, the user function menu should be opened