SATLINK FLEET ONE Installation Manual Ref: SL00-01191 Ver: 003
Page 21 of 38
Proprietary Information Not To Be Disclosed Without Written Authorisation From
Satlink S.L., All Rights Reserved
The following important notes are to be followed for the selection of a location before
installing the BDU:
The unit is not water proof and it has to be kept away from water splash.
The ambient temperature and humidity in the selected location must the requirements
given in the unit’s specification.
Ambient Temperature -25ºC to +55ºC
Relative Humidity Up to 95% at +40ºC.
The unit shall be kept away from direct sunlight.
The unit shall be placed away from any high vibration and shock areas (for example,
motor engine and generator) as far as possible.
The unit shall be kept away from other electronic equipment.
The unit has to follow the recommended compass safe distance of 1m to prevent
interference to a magnetic compass
For maintenance and checking, the unit’s location has sufficient space at its sides
and rear.
The BDU comes with a cable support item, which is included in the delivery. The cable
support item is to secure the cables from the BDU.
To mount the cable support onto the BDU,
Remove the 2 screws of the front mounting bracket
Mount the cable support item on the bottom of the BDU.
Tighten the same 2 screws to secure the cable support item.