Label/Tag Select
Command Structure <ESC>YEa
a = 0 Adhesive labels on liner
1 Tags
Example: See above
Placement: Separate data stream sent to the printer.
Default: Printer default setting
Command Function To select adhesive backed labels or non-adhesive tags
Input to Printer
<ESC>A
<ESC>YE0
<ESC>Z
Printer Output There is no printer output for this command
Special Notes 1. When power is recycled, the Label/Tag setting returns to the default
value specified by the <ESC>PG command. To change the
default setting in the printer, use the <ESC>PG Printer
Configuration command or the Printer Setting Utility program on
the CD-ROM.
2. This command is used to control last label printing. If Label is
selected, the printer will stop printing as soon as a Label Out
condition is detected. If Tag is selected, the printer will continue to
print after a Label Out signal is detected until the current label is
printed.
Section 4. Programming Reference
SATOCT SeriesPrinters9001069A Page4-51