Section 3. Confi
uration
LABEL RE-DETECT
E
NABLE DISABLE
IEEE1284
ACK SIGNAL 00.5
This selection allows the user to disable the feeding of a blank
label upon power up. If Enable (default) is selected, the printer
will automatically feed a label until it detects a label end. This
will correctly position the next printed label under the print
head. If Disable is selected, the
printer will not try to detect the
next label and the operator is responsible for ensuring that the
label is correctly positioned before printing.
If the printer is placed in the Single Item Buffer Mode (DSW2-5
= ON), this selection allows the user to set the width of the
IEEE1284 ACK pulse. In the Multi-Item Buffer Mode, this
display will be skipped.The range is 0.5 µsec to 10 µsec.
1. Use the LINE key to step
the display to the desired setting.
The setting will advance in increments of 0.1 µsec each
time the LINE key is pressed until the setting reaches 10.0
µsec when it will wrap around to the 0.5 µsec setting.
2. Once the desired setting is selected, press the FEED key to
accept
the setting and step to the next display.
HEX DUMP
N
ORMAL HALF
SATO
“Se”
Print En
ines Pa
e 3-25
IP ADDRESS
000.000.000.000
SAVE USER DEF
RFID MODE
YES N
O
LAN CONFIGURATION
B
OARD LCD
If no RFID kit is installed in the print engine, select No in this
menu to hide the RFID Mode options. Otherwise, use the
LINE key to select Yes, and then press the FEED key.
This selection appears, if a LAN (excluding WLAN) board has
been installed in the printer. The menu lets you select whether
the LAN configuration set on the interface card is to be used,
or whether the LAN configuration set via the printer’s firmware
using the LCD screen, is to be used. The default configuration
to be used is the Board’s settings. Use the LINE key to
choose the desired setting, and press the FEED key to
continue. (Note: LAN configurations set on the printer will not
change the board’s LAN configuration. After setting a LAN
configuration via the LCD menu, you need to turn the printer
OFF and then ON to let the new settings take effect.)
This and the next two subsequent menu screens, only appear
when a LAN interface board has been installed, and the LAN
CONFIGURATION option has been set to LCD.
Use the LINE and FEED keys to select and change each digit
of the IP ADDRESS, SUBNET MASK and GATEWAY
ADDRESS to the correct values in your LAN network.
Permissible values at 0 to 255 for each of the four segments of
an address.
SUBNET MASK
000.000.000.000
GATEWAY ADDRESS
000.000.000.000
This selection determines if the Hex Dump printout for a standard
4” print head, contains 16 bytes (Normal) or 8 bytes (Half) of data
per line. The default is Normal. Use the LINE key to select either
option, and then press the FEED key to continue.
This selection lets you save your current printer settings. In case
any subsequent changes to the settings result in operational
errors, you can restore your saved printer settings to resume work.
Select Yes or No with the LINE key, and the press the FEED key
to return to the main Service Mode menu.
YES N
O