Troubleshooting www.schaerer.com
47
BASCA - EN
Version 03 04.2008
Display message Cause Remedy
select product
water ow error
Possible causes:
No water connection
Defective pump (pump pressure < 7.5
bar)
Brew unit blocked
Water system blocked
Grinder mixture too ne
PCB - owmeter incorrectly connected
Electrical problem (PCB, ...)
Open the shut-off valve and press the beverage
button again.
Check the brew unit.
Check the grinder mixture.
If the message remains on the display: Contact
a qualied service technician.
select product
over temp. brewwater
Electrical problem between the sensor
and the PCB.
Temperature sensor defective.
Contact a qualied service technician.
select product
over temp. tea
Electrical problem between the sensor
and the PCB.
Temperature sensor defective.
Contact a qualied service technician.
select product
over temp. steam
Electrical problem between the sensor
and the PCB.
Temperature sensor defective.
Contact a qualied service technician.
selection locked
heating coffee water
The temperature is 10 °C below the pro-
grammed temperature.
Beverage output is blocked!
Wait until the target temperature has been
reached.
If the message remains on the display: Contact
a qualied service technician.
selection locked
heating hot water
The temperature is 10 °C below the pro-
grammed temperature.
Beverage output is blocked!
Wait until the target temperature has been
reached.
Bleibt die Meldung bestehen: Qualizierte Serv-
icestelle kontaktieren.
selection locked
heating steam
The temperature is 10 °C below the pro-
grammed temperature.
Beverages can not be dispensed when
the temperature is below 110 °C.
Wait until the target temperature has been
reached.
If the message remains on the display: Contact
a qualied service technician.
select product
timeout coffee heater
The programmed temperature of the
coffee water boiler was not reached
within 4 minutes after the machine was
switched switched on.
Beverage output is blocked!
Switch the machine off and then back on.
If the message remains on the display: Contact
a qualied service technician.
select productHW
heater timeout
The programmed temperature of
the hot water boiler was not reached
within 4 minutes after the machine was
switched switched on.
Hot water beverage output is blocked!
Switch the machine off and then back on.
If the message remains on the display: Contact
a qualied service technician.
select product
steam heater timeout
The programmed temperature of the
steam boiler was not reached within 4
minutes after the machine was switched
switched on.
Milk and steam beverage output is
blocked!
Switch the machine off and then back on.
If the message remains on the display: Contact
a qualied service technician.
selection locked
coffee sensor def.
Possible causes:
Electrical problem between the sensor
and the PCB.
Temperature sensor defective.
Contact a qualied service technician.
selection locked
HW sensor def.
Possible causes:
Electrical problem between the sensor
and the PCB.
Temperature sensor defective.
Contact a qualied service technician.
selection locked
steam sensor def.
Possible causes:
Electrical problem between the sensor
and the PCB.
Temperature sensor defective.
Contact a qualied service technician.
selection locked
brew unit time out
The brew unit motor is not running.
Beverage output is blocked!
Contact a qualied service technician.

Table of Contents