Operation www.schaerer.com
Option 2: Cup & Cool
► Switch on the cup warmer unit via the main switch (1).
The switch lights up.
► Switch on the cooling unit via the main switch (2).
The switch lights up.
A detailed description of how to set the thermostats (see arrow) can be found in the separate
operating instructions for the "Cup warmer and Cup & Cool".
Option 3: Integrated cooling unit
► Remove the left front cover.
► Switch on the toggle switch at the top left.
The switch lights up green.
The temperature is preset at the factory.
► Mount the front cover again.
Option 4: Side cooling unit
► Connect the side cooling unit to the power supply.
► Turn the rotary switch clockwise to the middle position.
► Check for a cooling temperature of 3 – 5°C and adjust the temperature setting if neces-
sary.
Be sure to observe the operating instructions for the side cooling unit.
Option 5: Under-machine cooling unit
Connecting:
► Connect the under-machine cooling unit at the rear using the separate mains cable
BA SCV_EN
V06 | 11.2015
33