INSTALLATION
20 | EN www.schmalz.com 30.30.01.01117/06
Table 5: Controller pin assignment
Plugs for connecting chain hoist and controller
Incorrect operating voltage / frequency
Material damage to chain hoist
Before connecting the chain hoist, check that the operating voltage /
frequency specified on the type plate matches the available voltage
supply.
The power must be supplied with a clockwise rotation field. Check the
rotation field before starting operations.
Open the terminals (Fig. 8).
5.2 Inserting a New Chain
Remove the old chain
1. Disconnect the chain from the main
body.
2. Unscrew the end stop (1).