INSTALLATION
22 | EN www.schmalz.com 30.30.01.01117/06
5.3 Adjusting the Limit Switch
A gear limit switch is fitted in the chain hoist as standard. This is also suitable as a regular end stop
with high switching precision. When starting operations, check that the system switches off at the end
stops (highest and lowest hook positions).
Load hook in highest position
Load hook in lowest position
Fig. 11
Fig. 12
The hook must be adjusted to its highest and lowest positions in turn in order to ensure
that the end stop (1) and the hook fitting (2) do not hit the housing.
Press and hold down the rocker (4) when inserting or replacing the chain in order to deactivate the
gear limit switch.
1
2
2