46
Overview
SP 500 / 750-15 / 750-18 / 1000 / 1250 Operation Manual
Pump Status Screen
The Pump Status Screen provides information on bat-
tery voltage along with installed options:
A. Hydraulic Oil Temperature
B. Hour Meter
C. Stroke Counter Readout -1
D. Stroke Counter Readout -2
E. Battery Voltage
F. Fuel Gauge
G. Stroke Counter Reset Symbol -1
H. Stroke Counter Reset Symbol -2
I. Message Center
J. Horn Silence Symbol
K. E-Stop Pressed Symbol
L. Manual Cycle - Auto Greaser
- Press to go to the Engine Status Screen
- Press
esc
to go to the Menu screen
9E
1/2
F
14
20 100
60
19
0000
000 000
ok
LEFT E-STOP
1 2
1 2
A C D E
FB
Menu Screen
The Menu Screen displays additional status and pa-
rameter settings screens indicated below:
• Pump Codes
• Engine Codes
• PLC I/O
• Operator Keypad
• Radio Remote
• Cable Remote
• Options
A small Schwing logo indicates which menu item is
currently selected. Use the to scroll up and down
the menu items. When you have moved the to the
screen you would like to access, press the
ok
button.
- Press
esc
to return to the Engine Status
Screen.
ok
esc
Pump Codes
PLC I/O
Operator Keypad
Radio Remote
Cable Remote
Engine Codes
Options
SP_PLC_ver-01.24.00F
SP_MMI_ver-01.21.00F
Pump Codes Screen
Displays pump code faults.
- Press
esc
to return to the Menu screen.
esc
00
CLASS USER SOURCE CAUSE