2. Make sure all product loaded is installed in the correct selecon. Load product according to the
machine Plan-O-Gram. A change from the Plan-O-Gram may require new setup. See the Loading
Beverage Lanes secon of this manual and study the Product Groups and how to load them and
accessories required (if any).
3. Make sure the Sensivity Adjust (Menu > 5 Opons > 9 Sensivity Adjust, see Programming secon
of this manual) is set properly. If the sensivity is set too high, the sensor may trip before the product
drops and stop the vend process prematurely. Under advisement from technical support,
change the sensivity from high to medium or medium to low and test vend.
My beverages are vending more than one at a me.
1. Make sure all items are loaded correctly. Review Loading Beverage Lanes secon of this manual and
verify all recommendaons and steps are followed for your type of packaging.
2. Make sure the Drop Sensor Sensivity (Menu > 5 Opons > 9 Drop Sensor, see Programming secon
of this manual) is set properly. If the sensivity is set too low, the sensor may not trip when the
product drops and perform a second vend. Under advisement from technical support, change
the sensivity from medium to high or low to medium and test vend.
The selecon vends ne in Test Mode, but during Sales Mode says Make Alternate Selecon.
1. You have an error code or a jam blocking the use of that parcular selecon. You will need to empty
all products and make sure there are no jams. Return the auger to the home posion and reload the
product. Then go to the menu and press 7 to recapture motors. This will allow you to resume vending
from that parcular selecon(s).
Power
I can see and hear the cooling deck fans, but there is no power to the rest of the machine. What does this
mean?
1. Check the transformer on the oor of the machine. There is a cover that goes over the transformer
with access to the small breaker switch on top of the transformer. Press the breaker switch to reset the
transformer. This should cause the machine to power back up.
2. Check to make sure that the main power harness that runs from the transformer to the VMC. Make
sure all connecons are good.