63QB2000 9.2022 vers 1.0
7. MACHINE WILL NOT COOL
a. Press the “#” key on the keypad to get a temperature reading
b. Verify that Temp Set is 43° F in Service Mode. Note: Seng the
temperature too cold will put your evaporator at risk of freezing up.
c. Verify that all fans are running
d. Clean the condenser
e. Remove your refrigeraon deck and inspect for ice.
Frequently Asked Quesons
Keypad
What do I do if my keypad isn’t responding, displays double the number pressed or displays a dierent
number?
1. If not responding, check the connecon at the VMC to make sure it’s secure. Examine the whole
keypad harness to make sure there is no damage to the harness.
Changer
My vendor won’t accept change, how do I x this?
1. Check to make sure the changer has power.
2. Check to make sure there are no coins jammed in the changer.
3. Check to make sure the coin return mechanism is releasing all the way.
What does it mean when the lights on top of the changer are ashing?
1. If the amber C/C light is ashing, it means that the lower coin cassee is not fully engaged. Remove
the lower coin cassee, line up correctly and reinsert.
2. If the red DIS light is ashing, it means that there is a jam located in the upper cassee. You can
clear that by opening the clear center access door or opening the ap on top to check for interior jams.
Bill Validator
My vendor won’t accept bills, what do I do?
1. In Menus, Sengs, check Qty/Tube for your coin values. Your bill validator operates only if it knows
that there is enough change in the Coin Changer to make transacons. The best way to make sure your
bill acceptor has this informaon is to make sure all coins are loaded when in the Qty/
Tube Menus mode and inserted through the front of the vendor.
2. Make sure the bill acceptor is clean and there are no jams or debris inside of the acceptor.
Beverage Vending
My beverages aren’t vending at all.
1. Make sure all items are loaded correctly.