EasyManua.ls Logo

Securimax Smart-Vent - Setup Functions and Configuration; System Fan Speed Control

Default Icon
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
To select any of the settings press SELECT
button.
* Setup Heater Mode option is displayed
only if the heater is installed and Enabled in
the Heater Option.
**Fan Mode option only applies to Eco
Smart-Vent models: SV01, SV02, SV04 &
SV06. It does not apply to Summer-Vent
models: SV02S, SV04S & SV06S.
To “exit” the Setup Mode at any stage:
Either: Press the MODE button and return to
Operational Mode:
Or: Wait 15 seconds and the controller will
time out to Operational Mode
System Fan Speed
The Smart-Vent controller uses a 2 or 3
speed motor to control the flow of filtered
air into the house. The householder
has control over the motor speed when
the ceiling temperature lies between the
minimum and maximum settings during
normal operation.
Above Maximum temp setting
- Automatic Fan Speed 1
Within temperature range
- Fan Speed 1, 2, and 3 available
Below Minimum temp setting
- No heater or disabled - Fan Speed 1
- Heater enabled - Fan Speed 2
Ceiling Temperature
When the ceiling temperature exceeds the
maximum temperature setting the fan speed
automatically sets to fan speed one (slow)
When the ceiling temperature drops below
the minimum temperature the fan speed
automatically sets to fan speed one if the
heater is disabled (or no heater is installed)
or speed two if the heater is enabled.
The controller uses a number 1,2 or 3 to
represent low, medium and high speeds and
a rotating icon on screen one of Operational
Mode to represent a fan running at speed.
MODE
5. Setup Functions
MODE
SELECT