follows: IM_SEC3_02.01_en.docx
38/70
Connectors
On-board connector (PBC) allows connection to SEC-3Q board by a standard RJ45 serial cable.
Trimmers
Trimmer PT1 adjusts the LCD contrast.
Buttons
When in normal mode:
• : OPEN door command
• : CLOSE door command
• : increase destination floor
• : decrease destination floor
• M : register a call to selected destination floor
• Clear = if pressed during 3 sec. clears the error that are disabling the lift operation. Obviously, if
the error still persists, the lift will be disabled again.
When in recall mode:
• : sets UP direction, in inspection speed
• : sets DOWN direction, in inspection speed
Programming
To enter PROGRAM MODE:
• press and hold M button for 3”; display will shows menu 00 “QUIT”
• press or to scroll menus
• press M to enter selected menu
• press: scroll parameters forward
• press: scroll parameters forward
• press: increase parameter value
• press: decrease parameter value
• press M to exit menu
To exit PROGRAM MODE:
• press Back per andare al menù 00 – “ESCI”
• press M
• press M
• press : save modification
• press : don’t save modification
Monitoring
Perss M + to scroll info pages:
• CALLS (car side A, car side B, down side A, down side B, up side A, up side B)
• CAR inputs (SEC-3C car board led’s and connectors monitoring)
• SHAFT signals (IU – ID)
• SOFTWARE revisions (controller, car, landind A and B side)
• ENCODER (with digital shaft only)
• GROUP (duplex, triplex, quadruplex)