follows: IM_SEC3_02.01_en.docx
57/70
Manual rescue operation instruction
AVAILABLE on BRUSHLESS GEARLESS only
Nominal speed reference setting – to be performed at lift commissioning
1. Set rated speed in parameter 50.01
2. Reset parameter 50.02 by pressing and holding 3 sec. both and buttons
3. Set parameter 50.02 to “Yes”; exit programming mode and save modification
4. Run few times the lift for a long travel, at full speed
5. Set parameter 50.02 and set it to “No”; exit programming mode and save modification
6. If direction shown is opposite to run command invert it at parameter 50.03
Rescue operation has to be performed by trained and qualified personnel!
1. Check that all the landing and cabin doors are closed
2. Open the IG mains switch (fig.1), and if present open IMT switch also
fig. 1
3. Turn and hold CFE key switch (fig.2)
fig. 2
a. the emergency sequence start
b. the controller is supplied and, after verifying time:
i. if the car is at a floor level the brake will not open, and the doors will be opened
ii. If car is not at a floor level and the doors are open, then the system will force a door
closing command
c. when doors will be closed and all the safety circuit is closed the brake will open, and the car
will move in the weight favourable direction