SC3 (monostable shaft switches)
1

Not used
2
IU/IZ1

UP magnetic switch/ DOOR ZONE magnetic
switch (ELGO Limax)
3
ID

DOWN magnetic switch
4
IZ/IZ2

DOOR ZONE magnetic switch
5
GND
SM1 (machine room safeties)
1
3
BRK: manual brake switch
4
6
Not used
SM2 (machine room safeties)
1
4
OSG: Over speed governor
SQ1 (controller interface)
1
Common Safety Circuit
3
Safety Circuit Start
5
Common Safety Circuit
SQ2 (recall drive)
1
3
RDF/ KINSP/BYPASS
5
7
RB - RDF
9
Safety Circuit End
SQ3 (ADO-ACL safeties)
1
3
DZSM
4
6
T30 TH TR
BYPASS landing door contact
(LOCKS)
SQ4 (ADO-ACL safety module interface)
1
2

UP sensor output
3
4

DOWN sensor output
5
6

DOOR ZONE sensor output
7
8

DOOR ZONE output
controlled by
SEC-3Q
9
DZSM control
10
GND
11
+24 VDC
12
GND
SQ5 (BYPASS)
1
BYPASS manual door contact
(SWING DOOR)
3
BYPASS car doors contact
(CAR DOOR)
SF1 (input pit inspection box)
1
input pit inspection box
2