Caution: Always wear proper PPE, including cut resistant gloves, when accessing the cutting chambers.
Tools and PPE Required:
Cut resistant gloves
7/16” and 3/4” wrenches or sockets
5/32” and 3/16” Allen wrenches
1. De-energize the unit using proper lockout-tag out (LOTO) procedures.
2. Open the Stage 2 cutting chamber access door (front door). See Figure 13.
Figure 13. Inside Stage 2 cutting chamber access door
3. Using a 3/4” socket wrench, remove the two painted side bolts that hold the cutting chamber drawer in
place. See Figure 14.
NOTE: Never operate the unit without these two painted bolts in place.