Doc No. 006-0211-00 Rev AK Page 7 of 33
INSTALLATION PROCEDURES FOR DOWNHOLE GAUGE
Installing the ESP Sensor with WYE Point Adapter to the Motor
It is recommended that the sensors be installed in a controlled environment or shop
prior to being sent to the field. If a sensor must be installed in the field follow the
procedures outlined below for sensors equipped with WYE point adapters.
1. Layout the sensor so that the three female connections on the Hockey puck
are aligned with the three pins coming out of the motor, and the holes on the
motor base are aligned with the holes on the motor head as shown in FIGURE 3.
2. Insure the O-ring has no sign of damage and install or replace with a new
O-ring if there are any signs of damage.
Figure 3: Aligning the motor pins to the Hockey Puck
3. Carefully stab the sensor into the motor, watching closely that the three pins
mate up with the three female connections on the hockey puck. IT IS VERY
IMPORTANT DURING THIS STEP YOU DO NOT TWIST THE SENSOR
WHILE STABBING INTO THE MOTOR BASE. DOING SO WILL RESULT IN
DAMAGING THE HOCKEY PUCK AND RUINING COMMUNICATION TO
THE SENSOR ONCE THE MOTOR IS STARTED.

Table of Contents

Other manuals for Sercel GRC Spy Pro

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sercel GRC Spy Pro and is the answer not in the manual?

Sercel GRC Spy Pro Specifications

General IconGeneral
BrandSercel
ModelGRC Spy Pro
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals