Operating instruction
PROSWING(M)
29
ID of the-
parameter
Description Adjustment
DEFAULT
setting
30
Polarity output Aux Out 1
0 = NO (Normally Open)
1 = NC (Normaly Close)
0
31
Polarity output Aux Out 2
0 = NO (Normally Open)
1 = NC (Normaly Close)
0
32
Force level during reset
RANGE: 0÷9 (0=force min,
9=force max)
5
tS
Automatic test
0 = No Test
1 = Ciclycal
2 = Ciclycal fast
0
Sd
Set to default
1-Select command with buttons [+] e [-];
2-Press [ENT];
3-Display [--];
4-Press again[ENT] for 5 seconds to confimr;
5-When disappears [--] release [ENT].
-
Lp
Learning cycle
1-Select command with buttons [+] e [-];
2-Press [ENT];
3-On display [--];
4-Press again[ENT] for 5 second to confirm;
5-When disappears [--] release [ENT].
-
During parameters setting any movement of motor is allowed.
When it is not used parameters setting, push button [ENT] is an opening command (only with One Radar or Two
Radars logics).