EasyManua.ls Logo

Sevcon MillipaK 4QPM - Cutback speeds

Sevcon MillipaK 4QPM
73 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Features Standard Features/Cutback Speeds
______________________________________________________________________________
MillipaK 4QPM Controller Manual Page 43 13/08/03
Cutback speeds
There are 2 cutback switch inputs as standard. Each one has an associated personality to adjust the
maximum % on when the switch is active. When both switches are active together, the lower
speed is selected. The cutback speed inputs are usually normally closed so that a wire off type
fault or bad connection initiates a lower speed.
Immediate Cutback Speed 1
Calibrator Menu Reference:
6.01
Minimum Maximum Step Size Typical Value
0% 100% 1% 100%
Immediate Cutback Speed 2
Calibrator Menu Reference:
7.01
Minimum Maximum Step Size Typical Value
0% 100% 1% 100%

Table of Contents