Controller Protection Under/Over Voltage Protection
______________________________________________________________________________
MillipaK 4QPM Controller Manual Page 61 13/08/03
Immediate High Voltage Cutout
Calibrator Menu Reference:
11.11
Minimum Maximum Step Size Typical Value
High V
Start
50.0V or
58.0V
0.5V 50.0V or 58.0V
The maximum High Voltage Cutout depends on the level of the System Voltage item. If the
System Voltage is set to 36V or lower, then the maximum is 50.0V. If the System Voltage is set
greater than 36V, then the maximum is 58.0V.