8
Installation
Installing options and accessories
Product Manual – MOVIDRIVE
®
system
237
8.7 Installing options and accessories
8.7.1 Installing a card
Observe the safety notes in the chapter "Electrical installation"(→2223).
For information on which option card can be installed in which slot, refer to the chapter
"Card slots".
1. Disconnect the application inverter from the power supply. Disconnect the DC24V
supply and the line voltage.
2. Ensure electrostatic discharge with suitable measures before starting work. Suit-
able measures for equipotential bonding include, for example, the use of a dis-
charge strap or wearing conductive shoes.
3. Remove the safety cover [1] from the front of the application inverter.
1.
2.
[1]
5
4
3
2
1
14299394571
4. Remove the plastic cover [1] of the card slot using a screwdriver.
[1]
15160620811
28487486/EN – 02/2019
8

Table of Contents

Other manuals for SEW-Eurodrive MOVIDRIVE system

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SEW-Eurodrive MOVIDRIVE system and is the answer not in the manual?

SEW-Eurodrive MOVIDRIVE system Specifications

General IconGeneral
CategoryInverter
SeriesMOVIDRIVE system
Output Voltage0 - Input Voltage
Protection ClassIP20, IP65 (depending on model)
TypeFrequency Inverter
Output CurrentVaries by model
Control MethodSensorless vector control, V/f control
Communication InterfacesCANopen
SafetySafe Torque Off (STO), Safe Stop 1 (SS1)
Input Voltage200-240V AC, 380-480V AC, 500-600V AC