8.6.2 Status LED L2 SEWOS
State LED Meaning Measure
Off No application loaded. No
SEWOS loader active.
Contact SEW‑EURODRIVE ser-
vice.
Red Error at the SEWOS loader during
starting process.
Contact SEW‑EURODRIVE ser-
vice.
Flashes red The SEWOS loader restarts the
entire system after system set-
tings have been changed.
Orange The SEWOS loader is starting.
Orange for
approx. 10s
and "BL7",
then flashing
red and "BL7”
for 2s, then
one of the fol-
lowing states
No network connection to
MNC45A controller
Check the network connection to
the device or contact
SEW‑EURODRIVE Service.
Flashes or-
ange
The SEWOS loader is active as
stand-alone. No application
loaded (status display "BLR").
Load the application software.
Green The SEWOS loader starts a
loaded application.
Flashing
green
The application has started and is
running.