10
Technical data
General
Operating Instructions – MOVIPRO
®
PHC2.A-A..M1-E45C-C5
165
10.2 General
Basic device
Size Size 1 Size 2
Performance class 2.2kW/4kW/7.5kW 11kW/15kW/22kW
Interference immunity Complies with EN61800-3
Interference suppression level A to EN55011
Interference emission Limit value class C3 to EN61800-3
Ambient temperature ϑ
U
+5–+40°C
Non-condensing, no moisture condensation
Device is intrinsically safe with respect to temperature. When the
temperature of the heat sink is too high, the device switches off and
the error message "Overtemperature" is issued.
Ambient temperature derating EN60721-3-3
Climate class Class 3K3
Storage temperature ϑ
L
-25–+70°C
Degree of protection IP54
Restrictions in use / installa-
tion altitude
• Up to h<1000m without restrictions.
• The following restrictions apply to heights ≥ 1000 m:
– From 1000m to max. 4000m:
I
N
reduction by 1% per 100m
– From 2000m to max. 4000m:
U
N
reduction by AC 6V per 100m
Mass 21kg 35kg
DimensionsW×H×D 570×300×189mm 660×420×202mm
10.3 Input data
Basic device
X121.
Size Size1 Size2
Performance class 2.2kW 4kW 7.5kW 11kW 15kW 22kW
Power supply Three-phase current
Input voltage range 3×AC380–500V
Line frequency f
line
50–60Hz
Supply current
(at U
line
=3×AC400V)
I
line
AC5A AC8.6A AC14.4A AC21.6A AC28.8A AC41.4A
26596598/EN – 10/2020