10
Technical data
DC 24 V backup voltage
Operating Instructions – MOVIPRO
®
PHC2.A-A..M1-E45C-C5
166
10.4 DC 24 V backup voltage
X121.
Nominal input voltage U
1_N
DC24V-15%/+20% (EN61131-2)
Own consumption ≤500mA (with 24V)/15W
Total power consumption Own consumption + output current on buses and I/Os
Nominal output voltage DC24V −15%/+20%
corresponds to PELV according to EN61800-5-1
Nominal output current DC 3A
Power limitation at 100W output power
10.5 Axis data
Size Size1 Size2
Performance class 2.2kW 4.0kW 7.5kW 11kW 15kW 22kW
Axis type PFA MD022B MD040B MD075B MD110B MD150B MD220B
Connection designation X2012_.. X2016_..
Nominal output power S1 ac-
cording to EN600341
2.2kW 4kW 7.5kW 11kW 11kW,
15kW with
optional
fan
11kW,
22kW with
optional
fan
at PWM frequency = 4 kHz
Nominal output current AC5.5A AC9.5A AC16A AC24A AC32A AC46A
Current limiting AC8.25A AC
14.25A
AC24A AC36A AC48A AC69A
Motor and regenerative, duration depending on the utilization
Output voltage 3 × AC 0–500V
PWM frequency Adjustable: 4/8/12/16kHz
Speed range - 6000–0–+ 6000min
-1
Resolution 0.2min
-1
over the entire range
Temperature sensor for single
drive
TF/TH/KTY: When using devices designed for group drive (2 motor con-
nections), the temperature sensor contacts on the motor connection not in
use must be jumpered.
Temperature sensor for group
drive
TH (series connection via both drives)
Maximum motor cable length 30m
26596598/EN – 10/2020