3
Device structure
Function units
Operating Instructions – MOVIPRO
®
PHC2.A-A..M1-E45C-C5
38
Fieldbus interface
The device is equipped with an UDP-capable Ethernet interface for connection to the
fieldbus. The fieldbus is connected via plug connectors. For more information, refer to
chapter "Electrical connections"(→271). The device has the following addresses in
delivery state:
Standard IP address: 192.168.1.99
Subnet mask: 255.255.255.0
Digital inputs and outputs
The device has connections for digital inputs or outputs. You connect the sensors and
actuators required for your application to the digital inputs and outputs. To connect
several sensors and actuators to the device at the same time, use the sensor/actuator
box which is available as an accessory. For more information, refer to chapter "Ac-
cessories" (→ 2 40). The following figure shows an example of an sensor/actuator
box connection:
[1]
[2]
33341932811
[1] Device
[2]
Sensor/actuator box with M23 connector and M12 connections, e.g. for:
Switches
Inductive sensors
Light barriers
Indicator lights
26596598/EN – 10/2020