5
Mechanical installation
Assembly
Operating Instructions – MOVIPRO
®
PHC2.A-A..M1-E45C-C5
53
5.5.2 Mounting using the through bores
In order to attach the device, it is equipped with 4 through bores in the corner profiles
with a diameter of 6.5mm and M8 threads on both sides.
The following figure shows the structure of the through bores in mm:
9
6.5
9
25
M8
40
M8
Z
20 5
[1]
[2]
45035996737806603
[1] Device
[2] Cooling fins
Z Height of through bore + T-slot
(see dimension drawings in chapter "Technical data"(→2164))
Required material
In order to comply with the required minimum clearances, use one of the following
mounting elements:
Suitable spacers
Mounting surface, e.g. mounting plate (with appropriate cut-out for long cooling
fins)
Suitable mounting and safety elements:
For mounting from the front (A): M6 screws of an appropriate length with wash-
ers
For mounting from the back (B): M8 screws of an appropriate length with wash-
ers
Suitable locking devices, e.g. lock washers
Suitable rubber buffers
26596598/EN – 10/2020