6
Electrical installation
Electrical connections
Operating Instructions – MOVIPRO
®
PHC2.A-A..M1-E45C-C5
82
Signal contact for external maintenance switch
The device has a signal contact for an external maintenance switch. If you do not use
an external maintenance switch, you must jumper the DC 24 V to the signal contact
(SC).
DC24V supply connection examples
1
2
3
1
2
3
4
5
6
7
8
PE
+24V_C
SC
VO24
0V24_C
GND
1
2
3
1
2
3
4
5
6
7
8
PE
+24V_C
SC
VO24
0V24_C
GND
[1]
[B]
[c]
[b]
[a]
[c]
[b]
[a]
[A]
[2]
[3]
[4]
33234185227
[A] Connection example of external DC24V supply
[B] Connection example of internal DC24V supply
[a] Han
®
C module, male [1] 24V external
[b] Han
®
EE module, male [2] 0V external
[c] Han
®
EE module, male [3] 0V internal
[4] 24V internal