UX-B20U/UX-B20C/B25C
2 – 9
SW
NO.
DATA
NO.
ITEM
Switch setting and function Initial setting
Remarks
10U/C
SW
l
B5
1
2
3
4
5
DTMF signal transmission level
(Low)
0
0
1
1
0
6Reserved 0
7Reserved 0
8Reserved 0
SW
l
B6
1
2
3
4
5
DTMF signal transmission level
(High)
0
0
0
1
1
6Reserved 0
7Reserved 0
8Reserved 0
SW
l
C1
1
2
Reading slice (Binary) Factory
setting
Light Dark Darker
in dark
0
0
No. 10101
No. 20011
3
4
Reading slice (Half tone) Factory
setting
Light Dark Darker
in dark
0
0
No. 30101
No. 40011
5 Line density selection Fine Standard 0 OPTION
6Reserved 0
7 MTF correction in half tone mode No Yes 0
8Reserved 0
SW
l
D1
1
2
3
4
Number of rings for auto receive 0
1
0
0
OPTION
5 Automatic switching manual to auto
receive mode
Reception after 5 rings No reception 0
6Reserved 0
7
8
Cl detect frequency As PTT 11.5Hz 13.0Hz 20.0Hz
0
0
No. 70011
No. 80101
SW
l
D2
1
2
3
Distinctive ringing setting (PATTERN
4 and 5 are for CANADA only)
No. 1 No. 2 No. 3 0
0
0
OPTION
OFF 000
STANDARD 0 0 1
PATTERN1 0 1 0
PATTERN2 0 1 1
PATTERN3 1 0 0
PATTERN4 1 0 1
PATTERN5 1 1 0
4Reserved 0
5 Caller ID function Yes No 0 OPTION
6 Caller ID detect during CI off All times Only first 0
7Reserved 0
8Reserved 0
Binary input
No.= 168421
1 2 3 4 5(nx0.5dBm)
EX0 0110
eg. Signal transmission level is set to -3dBm.
Binary input
No.= 168421
1 2 3 4 5(nx0.5dBm)
EX0 0011
eg. Signal transmission level is set to -1.5dBm.
Binary input
No.=8421
1234
EX0100
eg. Number of rings for auto receive is set to 4times.