⑦Key-switch section
(RUN)KEY:
Press for 3 seconds at STBY (control stop), then FIX or PROG control starts. Press for 3 seconds
while FIX or PROG is in operation, then control is stopped.
(MENU)KEY:
Press this key to move onto the next screen among the screens.
en of FIX or PROG, then it jumps
on the screen of operation mode 2, then it jumps to the screen of operation Mode 1.
(Shift) key:Move the digit which set the value
The digit can be changed are blinked.
(Down) key:
continuously, the value as well consecutively decreases.
A decimal point of the smallest digit blinks at this time.
(Up) key : By
pressing continuously, the value consecutively increases. A decimal point of the smallest digit blinks
at this time.
MODE1 MODE2 MODE3 MODE4 MODE14
-8 from FIX mode lead screen
SV№1 FIX SV№ 2 SV№ 8
-8 from Program mode lead screen.
Pattern 1 Pattern 2 Pattern 8 Pattern common setting