VM-7 System Manual
Chapter 2 Description of the System
14
<Absolute Vibration Monitor Module (VM-702)>
The Vibration Monitor Module is a dedicated monitor that monitors the relative/absolute vibration
level of the rotary machine shafts, or relative vibration and seismic vibration simultaneously.
This module is compatible with up to 2 input systems (relative vibration: 2 channels, seismic
vibration: 2 channels).
Also, this module provide the recorder output corresponding to input signals and contact output, to
outside equipment via the rear panel of the instrument rack.
No. Name Function
1ch OK indicator
When 1ch is normal: Lights (in green).
When 1ch warning is activated: Flashes.
2ch OK indicator
When 2ch is normal: Lights (in green).
When 2ch warning is activated: Flashes.
3ch OK indicator
When 3ch is normal: Lights (in green).
When 3ch warning is activated: Flashes.
4ch OK indicator
When 4ch is normal: Lights (in green).
When 4ch warning is activated: Flashes.
1ch monitor output
connector
Outputs 1ch input signal via the buffer amplifier.