EasyManua.ls Logo

Shure AD4D - System Audio Polarity; Operating Temperature Range; Storage Temperature Range; Audio Output

Shure AD4D
42 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Shure Incorporated
38/42
System Audio Polarity
Positive pressure on microphone diaphragm produces positive voltage on pin 2 (with respect to pin 3 of
XLR output) and the tip of the 6.35 mm (1/4-inch) output.
Operating Temperature Range
-18°C (0°F) to 50°C (122°F)
Note: Battery characteristics may limit this range.
Storage Temperature Range
-29°C (-20°F) to 65°C (149°F)
Audio Output
Gain Adjustment Range
−18to+42dBin1dBsteps(plusMutesetting)
Configuration
XLR
TransformerCoupledBalanced(1=ground,2=au
dio+,3=audio−)
TRS
Transformer Coupled Balanced (Tip = Audio +,
Ring = Audio -, Sleeve = Ground)
Impedance
100Ω,Typical,XLRLineOut
Full Scale Output ( 200K Ωload)
LINE setting +18dBV
MIC setting −12dBV
TRS +8dBV
Mic/Line Switch
30 dB pad
Phantom Power Protection
Yes
Dimensions
44x483x333mmHxWxD
Weight
4.6kg(10.1lbs),withoutantennas
Housing
Steel; Extruded aluminum

Table of Contents