Command String:
< SET METER_RATE_POSTGATE sssss >
Where sssss is a value from 0 to
99999 in milliseconds.
0 = Off
100 = Minimum value
99999 = Maximum value
MXA910 Response:
< SAMPLE aaa bbb ccc ddd eee fff ggg hhh >
Where aaa, bbb, etc is the value of
the audio level received and is
000-060.
aaa= output 1
bbb= output 2
ccc= output 3
ddd= output 4
eee= output 5
fff= output 6
ggg= output 7
hhh= output 8
Get Automixer Gain Metering Rate (firmware > v3.0)
Command String:
< GET METER_RATE_MXR_GAIN >
MXA910 Response:
< REP METER_RATE_MXR_GAIN sssss >
< SAMPLE aaa bbb ccc ddd eee fff ggg hhh >
Where sssss is the metering rate in
milliseconds. Setting sssss= 0 turns
metering off.
Set Automixer Gain Metering Rate (firmware > v3.0)
Command String:
< SET METER_RATE_MXR_GAIN sssss >
Where sssssis a value from 0 to
99999 in milliseconds.
0 = Off
100 = Minimum value
99999 = Maximum value