Specifications
System RF
RF Carrier Frequency Range
470–937.5 MHz, varies by region (See Frequency Range and Output Power table)
Working Range
100 m ( 328 ft)
Note: Actual range depends on RF signal absorption, reflection and interference.
RF Tuning Step Size
25 kHz, varies by region
JB band: 125 kHz
Image Rejection
>70 dB, typical
RF Sensitivity
−97 dBm at 10 BER
System Temperatures
Operating Temperature Range
-18°C (0°F) to 50°C (122°F)
Note: Battery characteristics may limit this range.
Storage Temperature Range
-29°C (-20°F) to 74°C (165°F)
Note: Battery characteristics may limit this range.
System Audio
Latency
3.2 ms
High-Pass / Low Cut Filter
150 Hz @ -12 db/oct
Note: Factory default is for the HPF to be off
Audio Dynamic Range
118 dB at 1% THD, Aweighted, typical