Technical Information Chapter 4
CLV61x
Electrical installation
8015592/ZNI9/2017-06-13 © SICK AG · Germany · All rights reserved · Subject to change without notice 41
4.8.2 Wiring the Supply Voltage in the CDM420-0001 Connection Module
4.8.3 Wiring the RS-232 Serial Host Data Interface in the CDM420-0001 Connection
Module
6
1
10
5
11
15
CLV61x
CDM420-0001
V
S
V
S
V
S
= DC 10 V to 30 V
1
5
5
Shield
1 +24 V
2 GND
+24 V*
GND
S1
F
Shield
D-Sub HD plug,
15-pin
GND
.
.
.
.
.
.
ON
OFF
S1 : POWER
DC 10 V to 30 V
+24 V*
Switch S1:
ON:
Power supply voltage U
V
(+24 V)
switched as U
V
(+24 V*) via fuse to
CDM420-0001 and CLV61x.
U
V
(+24 V*) additionally available on terminals 29 and 39.
OFF:
CDM420-0001 and CLV61x disconnected from power supply voltage.
Recommended position during all electrical installation work.
POWER
V
S
on terminal "+24 V" complies with terminal "+24 V*" after fuse F and switch S1
6
1
10
5
11
15
CLV61x CDM420-0001 Host
D-Sub
HD plug,
15-pin
5
.
.
.
TxD
RxD
RxD
TxD
GND
GND
GND
9
7
34
T‒/TxD
35
R
‒/RxD
36
GND
6
Shield
RS-232
RS-232
ON
OFF
S2 : RS 485
ON
OFF
S3: Term 422
S2
OFF485