Input values
Rel. Adr. Description
0 Current distance in the selected resolution taking into account the offset
and measuring direction.
Type
Signed 16-bit number in two´s complement
Module parameters
Name Description
Distance Resolution Select the resolution for the distance output value via the digital data
interface. The output value corresponds to the measured value [mm]
divided by the selected resolution. The parameter does not have any
influence on the measured value shown on the display.
Options
0.1 mm
0.125 mm
1 mm
10 mm
100 mm
free Distance Resolution
Factory setting
0.1 mm
free Distance Resolu‐
tion [μm]
Determines the resolution of the distance value if the free Distance Resolu‐
tion value has been selected in the Distance Resolution parameter.
Options
1 ... 100,000 [μm]
Factory setting
100 [μm]
10.3.3 Module 3: Speed/i2w
Type
Input module, 2 words, consistent
Description
This module reads the currently determined speed.
NOTE
If there was no valid measured value due to a device fault, a missing reflector or
contamination, then the value 0 is output for the speed and the corresponding bits are
set in the status bytes.
Input values
Rel. Adr. Description
0 Current speed in the selected resolution taking into account the direction
of measurement.
Type
Signed 32-bit number in two´s complement
10 PROFINET IO INTERFACE
60
O P E R A T I N G I N S T R U C T I O N S | DL100 Pro PROFINET HighFeature 8021823/19HC/2021-10-15 | SICK