Operating Instructions Chapter 3
DME4000
8014584/ZN33/2017-07 © SICK AG • Germany • Subject to change without notice 81
Menu Structure
Offset
Possible settings: ± 250 m
If there is a negative measured value, “0” is output via the SSI interface.
When the preset function is activated, the offset value is overwritten if the present input is triggered;
also refer to Chapter 9.1 “Preset”.
Plausibility
This function monitors measured values for plausibility. Responds at light beam interruption, vehicle
speed > 10 m/s and soiling. Plausibility error results in measurement value output 0.
Off
Normal
200 ms (Default)
No check
Check in measurement cycle
Error suppression
max. 200 ms.
Temperature
Display of the current sensor temperature.
Reset
NO
YES
No reset
Reset to default values
Note
Note