EasyManua.ls Logo

SICK GLS621 - Replacing the Device

SICK GLS621
62 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NOTE
To enable efficient processing and allow us to determine the cause quickly, please
include the following when making a return:
Details of the contact person
Description of the application
Description of the fault that occurred
9.6 Replacing the device
Replacing a device with transfer of the current configuration data
The current configuration data of the device to be replaced can be transferred to a
replacement device in several ways. The configuration data of the device is combined
as a parameter set. The replacement device saves the parameter set to the permanent
parameter memory.
Prerequisites:
The replacement device is a device of the same type.
The current configuration data of the device to be replaced is accessible in a
storage medium outside the device.
The available options depend on the backup concept chosen by the user at the time of
installation and configuration of the device to be replaced.
The first method is performed automatically by the device. The second method is
operated manually by the user.
Available options for transferring the configuration data:
1 Transfer of the current configuration data using the optional microSD memory
card removed from the device to be replaced.
Prerequisite:
If there is sufficient memory capacity on the microSD memory card, the configura‐
tion data from the last save operation in the device with the Permanent option was
automatically saved on the memory card.
It is not necessary to connect a computer with the SOPAS ET configuration soft‐
ware for transfer to the replacement device.
2 Transfer of the current configuration data by means of a download from the
computer.
Prerequisite:
The configuration data of the device was saved on the computer. This took place
on completion of configuration of the device that is now to be replaced with the
SOPAS ET configuration software after confirmation by the user.
NOTE
For further information see "Initial commissioning", page 41.
Removing the device to be replaced:
CAUTION
Risk of injury due to hot device surface.
The surface of the device can become hot during operation.
Before commencing disassembly, switch off the device and allow it to cool down
as necessary.
9 TROUBLESHOOTING
48
O P E R A T I N G I N S T R U C T I O N S | GLS621 8024289/19E9/2020-10-21 | SICK
Subject to change without notice

Table of Contents

Related product manuals