Operating Instructions Chapter 5
ICR890
Electrical installation
8011325/0000/2006-10-24 © SICK AG · Division Auto Ident · Germany · All rights reserved 73
“OUT“ connection (digital switching outputs)
“IN 1“ connection (digital switching input 1)
“IN 2“ connection (digital switching input 2)
“HOST ETHERNET“ connection (Ethernet 10/100 MBps)
Pin Signal Function
1 Result 1+ Switching output 1
2 Result 1– Switching output 1
3 Result 2– Switching output 2
4 Result 2+ Switching output 2
Tab. 5-23: ICD890 Camera: Pin assignment of the 4-pole M12 plug “OUT“
Pin Signal Function
1 +24 V DC Power supply for sensor
2 IN 1– Switching input 1 (optocoupler)
3GND Ground
4 IN 1+ Switching input 1 (optocoupler)
5–
Tab. 5-24: ICD890 Camera: Pin assignment of the 5-pole M12 socket “IN 1“
Pin Signal Function
1 +24 V DC Power supply for sensor
2 IN 2– Switching input 2 (optocoupler)
3GND Ground
4 IN 2+ Switching input 2 (optocoupler)
5–
Tab. 5-25: ICD890 Camera: Pin assignment of the 5-pole M12 socket “IN 2“
Pin Signal Function
1 TD+ Transmitter+
2RD+ Receiver+
3 TD– Transmitter–
4RD Receiver
Tab. 5-26: ICD890 Camera: Pin assignment of the 4-pole M12 socket “HOST ETHERNET“