NOTE
Assign the functions for the digital inputs in the device using a configuration tool, e.g.
the configuration software SOPAS ET.
13.7.8 Wiring digital inputs “External input 1” and “External input 2” of the device in the CDM420-0001
Device = Lector621 ECO = V2D621x-xxxxxYx (serial variant, Y = D or E)
Device 4
CDM420-0001
PNP sensor 7
V
S
GND
3.32 K
6.64 K
V
in
Out
GND
S6
CMC600 3
Aux
(RS-232)
ON
OFF
S6 : SGND
No
YES
S8 : CMC
17
SGND
8
Shield
39
+24 V*
A
Aux In B
+24V*
“External
input C” 5
SensGND
Trigger sensor 1
8
E.g. photo-electric
switch 6
2
Figure 81: Trigger sensor supplied with power by connection module CDM420-0001
1
Trigger sensor, e.g. for read cycle generation
2
Input voltage V
in
3
The optional CMC600 parameter cloning module is required in the connection module in order to be able to use the
additional external digital inputs and outputs of the device
4
Device
5
Logical “External input” in the device
6
e.g. photoelectric sensor
7
PNP sensor
8
Supply voltage V
S
CDM420-0001
PNP sensor 4
V
S
GND
Out
GND
S6
V
S ext
V
in
CMC600
No
YES
S8 : CMC
ON
OFF
S6 : SGND
17
SGND
8
Shield
39
+24 V*
A
Aux In B
+24V*
SensGND
Trigger sensor 1
5
2
3
CDM420-0001
V
in
GND
S6
CMC600
ON
OFF
S6 : SGND
No
YES
S8 : CMC
17
SGND
8
Shield
39
+24 V*
A
Aux In B
+24V*
SensGND
3
1
V
S ext
GND
A
17
2
2
Figure 82: Left: Trigger sensor connected potential-free and supplied with power externally. Right: Alternatively switch,
!
sup‐
plied with power by connection module CDM420-0001 or
"
connected potential-free and supplied with power externally.
Switch setting S3 then as in left figure.
ANNEX 13
8022502/15NT/2020-02-11 | SICK O P E R A T I N G I N S T R U C T I O N S | Lector621
125