Loading...
The device now ignores all further external read cycles. The device does not output
any read results via the host interface. The beeper confirms this process with an
ascending melody.
The Read Diagn function is preselected as the first function (LED is lit).
2. Press the arrow button () repeatedly until the LED of the desired function lights
up. The device runs through all possible functions step-by-step without executing
them and then starts again from the beginning. The beeper confirms every step
with a tone.
3.
Press the return key (p) to confirm the selected function.
The LED of the selected function now flashes and the beeper confirms start with a
double beep.
The device executes the function and automatically returns to read mode after
5 minutes without button operation.
The device automatically ends the TeachIn (for match code), Auto-Setup and Autofo‐
cus (Lector621 variant only) functions when the device has successfully read the
presented code. The assigned LED lights up green and the beeper confirms the
successful read with an ascending melody.
4.
To manually end (cancel) a function, press the return button (p) again and hold
for 3 seconds.
The beeper confirms the change with an ascending melody. The Ready LED lights
up again.
The device is ready for reading and is waiting for a read cycle.
NOTE
With the Auto-Setup function, make sure that a medium-high object is in the reading
field.
Table 5: Device functions (second display level for action with function buttons)
Display LED Color Status
Read diagn Lights up Blue Test (reading diagnostics) selected
Flashing Blue Test started
TeachIn Lights up Blue Teach-in selected (default: Match code)
Flashing Blue Teach-in started
Lights up Green Teach-in successful
Lights up Red Teach-in unsuccessful (Default setting: match code, the
device was not able to teach in any code)
Auto-Setup
Lights up Blue Auto-Setup selected
Flashing Blue Auto-Setup started
Lights up Green Auto-Setup successfully quit
Lights up Yellow Auto-Setup was partially successful
Lights up Red Auto-Setup was unsuccessful
Autofocus
1)
Lights up Green Function can be defined by user
Lights up Yellow Function can be defined by user
Lights up Blue Function can be defined by user
Lights up Red Function can be defined by user
1)
No applicable for Lector621 ECO
3 PRODUCT DESCRIPTION