Error code SOPAS ET hex code /
device status
Meaning Countermeasure(s)
Laser error 0x11 / Laser warning
0x60 / Laser error 1
0x61 / Laser error 2
0x62 / Laser error 3
Laser error Please contact the manu‐
facturer's technical support
Internal error 0x80 / Internal error 1
0x81 / Internal error 2
0x82 / Internal error 3
0x83 / Internal error 4
Operating fault Check the electrical envi‐
ronment and improve it, if
necessary (stability, voltage
supply, EMC influences). If
the error cannot be recti‐
fied: Please contact the
manufacturer's technical
support.
If a different message is output, please contact the manufacturer's technical support.
12.3 Information for service cases
You should collect and write down the following device information ahead of time if you
need to contact the manufacturer's service department:
Information about the firmware version
Information about the hardware
Information about operating hours
This information can be accessed via SOPAS AIR.
12.4 Returns
Do not dispatch devices to the SICK service department without consultation.
NOTE
To enable efficient processing and allow us to determine the cause quickly, please
include the following when making a return:
Details of the contact person
Description of the application
Description of the fault that occurred
12.5 Repairs
Repair work on the device may only be performed by qualified and authorized person‐
nel from SICK AG. Interruptions or modifications to the device by the customer will inva‐
lidate any warranty claims against SICK AG.
12.6 Disposal
CAUTION
Risk of injury due to hot device surface.
The surface of the device can become hot during operation.
b
Before commencing disassembly, switch off the device and allow it to cool down
as necessary.
12 TROUBLESHOOTING
60
O P E R A T I N G I N S T R U C T I O N S | OD1000 8019642/ZJW1/2017-04-03 | SICK
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK OD1000 and is the answer not in the manual?

SICK OD1000 Specifications

General IconGeneral
BrandSICK
ModelOD1000
CategoryAccessories
LanguageEnglish

Related product manuals