The response time T
S
of the LiDAR sensor depends on:
the base response time of the LiDAR sensor
whether multiple sampling is set
the filter settings (e.g., particle filter).
ZR supplement
This supplement must be determined on an application-specific basis and taken into
account appropriately. The following factors can make it necessary to use a supple‐
ment: reflectors or shiny objects on the scan plane, multi-echo analysis, blanking size,
device filter (e.g., particle filter).
3.6.8.2 Switching field width
The width of the switching field must cover the width of the vehicle and take into
account the supplements for the measurement error.
The switching field width SB can be calculated using the following formula (guideline
values based on a pixel calculation):
SB = FB + 2 × (ZG + ZR)
FB = Vehicle width
ZG = General safety supplement for the LiDAR sensor = 100 mm
ZR = Supplement for application-related influences or the selected application parame‐
ters