6.2 Description of the terminals
Figure 10: Terminals of the UE410-SD
Table 2: Terminals of the UE410-SD
Assignment Description
I1 Selection of the operating mode
•
U
B
t
o I1: Only sensor pair A active
•
Open: Sensor pair A and sensor pair B active
I2 Configuration for output Q3
•
U
B
t
o I2: Higher-level control at Q3
•
Open: Reset required indicator light at Q3
I3 No function
I4 Connection for reset pushbutton
A1 (+ U
B
) UE410-SD voltage supply
A2 (GND)
Y1 Application diagnostic output for sensor pair A
Y2 Application diagnostic output for sensor pair B
Q1 / Q2 Safety outputs (OSSD)
Q3 Connection for r
eset required indicator light or connection to a higher-
level control