10 Hz variant
Ambient operating temperature
(UL/C
SA: ambient temperature)
–40 ... +60 °C
1)
Object with 90 % r
emission (based on standard white DIN 5033).
2)
With light/dark ratio 1:1.
3)
Signal transit time with resistive load.
4)
A = U
V
-connections reverse polarity protected
C = Interference suppression
D = outputs overcurrent and short-circuit protected
13.3 Data sheet UE410-SD
Table 10: Supply circuit (A1, A2)
Minimum Typical Maximum
Supply voltage U
B
19.2 V DC +24 V DC 30 V DC
Type of supply voltage PELV or SELV
T
he current for the voltage supply must be limited exter‐
nally to max. 6 A – either by the voltage supply itself or
using a fuse.
Residual ripple – – 3 V
Power consumption – – 3 W
Maximum power-up delay after
po
wer-up
– – 10 s
Short-circuit protection 4 A gG with trigger characteristics B or C
Table 11: Input circuit I1–I8
Minimum Typical Maximum
Number of inputs: – – 8
Input voltage (high) 13 V DC – 30 V DC
Input voltage (low) –5 V DC – 5 V DC
Input current (high) 2.4 mA 3 mA 3.8 mA
Input current (low) –2.5 mA – 2.1 mA
Input capacity 9 nF 10 nF 11 nF
Minimum power-up delay I5/I6 and
I7/
I8
200 ms – –
Reset time – – 124 ms
Discrepancy time – – 3000 ms
Delete discrepancy error – – 350 ms
Actuating duration of the reset push‐
but
ton (I4)
50 ms – 5 s
Table 12: Control outputs (Y1, Y2)
Minimum Typical Maximum
Number of outputs – – 2
Type of output PNP semiconductor, short-circuit protected, cross-circuit
de
tection
1)
Output voltage 16 V DC – 30 V DC
Output current – – 120 mA
Load capacity – – 1.000 nF
TECHNICAL DATA 13
8021417/2018-01-17 | SICK O P E R A T I N G I N S T R U C T I O N S | UE410 Safeguard Detector Box
39
Subject to change without notice