Tableau 6: Conditions d'utilisation
Recommended sensing range for the best
performance
0
20
80
60
40
120
100
140
400 800
1,200
1,600
0
1
3
6%/90%
90%/90%
y
x
Minimum distance in mm (y) between the set sensing
range (x) and white background (90 % remission)
Distance in mm
2
18%/90%
Black object (6 % remission)
Set sensing range x = 500 mm
Needed minimum distance to white
background y = 25 mm
Example:
Safe suppression of the background
yx
White
background (90 %)
Illustration 3: Caractéristique, WTS26P
1
Distance de commutation sur noir, 6% de rémission
2
Distance de commutation sur gris, 18% de rémission
3
Distance de commutation sur blanc, 90% de réflectivité
Distance in mm (inch)
150
(5.91)
300
(11.81)
500
(19.69)
700
(27.56)
1,000
(39.37)
0
1
2
3
40 750
25
10
150
150
150
900
1,000
D
C
A B
BluePilot
E
F
Recommended sensing range for the best performance
Illustration 4: Graphique à barres, WTS26P
NOTICE D’INSTRUCTION
8020355.1GI9/2022-07-13 | SICK N O T I C E D ’ I N S T R U C T I O N | WTS26
75
Sujet à modification sans préavis
fr