Maintenance
9.1 Inspection and maintenance
Synchronous/induction motors 1PH813
68 Operating Instructions, 04/2009, 610.48000.22
Note
The fan should be cleaned with a suitable cloth or brush, and steps should be taken to
prevent moisture from entering the motor.
Once the voltage has been disconnected on all poles, wait for five minutes before
touching the device.
Never open the device during operation.
Never loosen any fixing screws for the ventilation unit during operation.
To clean the fan, remove the guard from the ventilation unit. The motor does not need to
be separated from the guard.
Once you have finished cleaning the device, screw the guard (with fan) back on to the
ventilation unit. When doing so, tighten the four screws to a torque of 4 Nm.