Maintenance
9.2 Repair
Synchronous/induction motors 1PH813
74 Operating Instructions, 04/2009, 610.48000.22
7. Insert the connector with signal cable and place the cable into the guide.
8. Attach the connector cover (2) with the screw (1) and secure (e.g. with Loctite 243).
NOTICE
With synchronous motors, the encoder system has to be realigned.
9.2.4 Removing/installing the rotor encoder
1 Screws 7 Clip
2 Cover 8 Connector
3 Balancing weight 9 Screws
4 Screws 10 Scanning unit
5 Cover 11 Rotor
6 Screw 12 Motor shaft
Figure 9-4 Built-in rotor encoder