Operating manual PA
100
36 Default settings
36.1 Temperature measurement via spectral channel 1 (configura-
tion layer: C001)
Parameter
Function
Default
User settings
EPS.1
Emissivity factor L1
99.0%, 99.%*
TAU.1
Transmission factor L1
100 %
BAC.1
Ambient temperature
compensation
Off
BAC.T
Temperature of
ambient source of radia-
tion
Off
BAC.%
Influence of ambient IR
radiation
--
LIN.1
Temperature offset using
linear interpolation
Off
L. X1
node x 1..10
--
L. Y1
node y 1..10
--
FIL.1
Smoothing filter
Off, Automatic*
FIL.T
Smoothing time
0.1 s
MEM.1
Min/Max memory
Off
MEM.T
Hold time for Min/Max
--
FIL.M
Smoothing filter for
min/max *
--
FIL.T
Smoothing time*
--
CLR.M
external delete for
Min/Max memory*
--
T.DEL
time delay**
--
T.ACT
meas. time active**
--
T.DIS
cut-off interval**
--
T.OUT
timeout**
--
LI. 1
Limit 1**
--
LI. 2
Limit 2**
--
F-PR
Average weighting**
--
TSP_
Threshold plausibility**
--
TSP~
Threshold plausibility**
--
ANO
Mode of display**
--
A.RST
Autoreset**
--
SAVE
Save
--
CH.L.2
Set Li2 check on tAct**
--
ESC
Escape
--
* Pyrometer PA 10 AFxx;
** Only available with ATD function